127 Huntley Cl
Twenty20 & Co Inc
May 3, 2026
"Designed to tell the real story."
⚠️ Tap Here
⚠️ Property Specs
elements
|
|
May 3, 2026 |
|
|
127 Huntley Cl Billings, Montana |
|
|
Attached 6PLEX |
|
|
Partly Sunny 12°C |
|
|
Agent (otherside) |
|
|
Lucas Kirsch
|
|
|
Emand Sandhu 1328 Kingston Place Emad72@gmail.com 2507524423 |
|
|
Kevin Gregus |
|
12:27PM Start Time |
method
This inspection is a visual, non-invasive review using normal controls & accessible areas.
We follow a consistent path through all major systems. Findings are structured for clarity so you understand what’s there, what needs attention & what to do next.
Each item lists the component or system, issue defect, recommended action & summary note.
Built to eliminate doubt.
"Turning information into decisions you can trust."
thank you
Thank you for choosing us for your inspection. We truly appreciate your trust.
I will be your primary contact & will do everything I can to ensure you are completely clear on today’s findings.
Please feel free to reach out at any time if you have questions or need further clarification. We’re always happy to help.
Kind Regards,
Lucas Kirsch
stuff.
A property inspection evaluates visible, non-exhaustive conditions & records findings in report form Inspectors examine readily accessible systems & components using a visual, non-invasive method & operate equipment using normal controls when possible. Components, issues, actions, location, trade & summary may be noted. Conditions reflect time of inspection only. Inaccessible or unsafe areas are not inspected (not accessible)
⚠️ We encourage you to read our Standards of Practice (SOP’s), scope, disclamers & limitations. The SOPs outline the scope of the inspection, the systems reviewed & the limitations that apply. They provide the framework inspectors follow to evaluate properties & communicate findings consistently. This structure helps ensure inspections are performed using a clear, proven, nationally recognized standard. Full details by clicking the logo. 🔻🔻🔻
The difference between something good and something great is attention to detail.
legends
![]() |
It’s a snap! Here are some key terms you’ll see throughout. |
| Iconography | Used for clarity. |
![]() |
Immediate Attention |
![]() |
Attention |
| Not Inspected | Limitations. |
| Hand Gestures | Universal. |
| Issue: | Identify the problem if there is one |
| Action: | Recommended path to address the issue |
| L: | Location where it is found |
| T: | Typical Tradesperson |
| R: | Reason why it wasn't inspected |
| $ / $$ / $$$ |
summary
Action: Install &/or Replace T: ⚫ Roofer L: All Scuppers
Notes: Attention – Issue(s) should be addressed in a timely manner. Poor drainage could lead to damage or water intrusion.
Action: Seal / Repair / Monitor T: 🟠 Ext-Envelope L: Throughout
Notes: Observation – Issue(s) should be monitored; plan for maintenance or correction as needed.
Action: Correct / Adjust / Verify T: 🟡 Electrical L: All Outlets
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this may increase risk of electrical issues.
Action: Seal / Repair / Monitor T: 🟠 Ext-Envelope L: All Faucets
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
summary
Action: Seal / Repair / Monitor T: 🟠 Ext-Envelope L: Throughout
Notes: Observation – Issue(s) should be monitored; plan for maintenance or correction as needed. Over time, minor wear may lead to gradual deterioration.
Action: Seal / Repair / Monitor T: General L: Multiple
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could lead to further deterioration and/or moisture intrusion.
Action: Seal / Repair / Monitor T: General L: Throughout
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Install &/or Replace T: General L: All Balconies
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
summary
Action: Correct / Adjust / Verify T: General L: All doors
Notes: Observation – Issue(s) should be monitored; plan for correction.
Action: Clean / Repair / Maintain T: WETT Inspector L: Living Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this may lead to reduced efficiency or buildup.
Action: Install &/or Replace T: 🟡 Electrical L: Backsplash
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Correct / Adjust / Verify T: General
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
summary
Action: Install &/or Replace T: 🟡 Electrical L: Unit #2
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Install &/or Replace T: 🟡 Electrical L: Unit #3
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Install &/or Replace T: 🟡 Electrical L: Unit #4
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Install &/or Replace T: 🟡 Electrical L: Unit 5
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
summary
Action: Further Evaluate / Repair T: General
Notes: Observation – Issue(s) should be monitored; plan for maintenance or correction as needed.
Action: Install &/or Replace T: 🟡 Electrical L: Unit #6
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Further Evaluate / Repair
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Correct / Adjust / Verify L: Unit #5
Notes: Observation – Issue(s) should be monitored; plan for maintenance or correction as needed.
summary
Action: Clean / Repair / Maintain L: Unit #5
Notes: Observation – Issue(s) should be monitored; plan for maintenance or correction as needed.
Action: Correct / Install T: 🟡 Electrical L: Bathroom
Notes: Immediate Attention – Issue(s) are critical or unsafe; corrective action required. Lack of protection may pose a risk of shock or injury.
Action: Correct / Install T: 🟡 Electrical L: Bathroom
Notes: Immediate Attention – Issue(s) are critical or unsafe; corrective action required. Lack of protection may pose a risk of shock or injury.
Action: Correct / Install T: 🟡 Electrical L: Bathroom
Notes: Immediate Attention – Issue(s) are critical or unsafe; corrective action required. Lack of protection may pose a risk of shock or injury.
summary
Action: Correct / Install T: 🟡 Electrical L: Bathroom
Notes: Immediate Attention – Issue(s) are critical or unsafe; corrective action required. Lack of protection may pose a risk of shock or injury.
Action: Repair &/or Replace T: 🔵 Plumbing L: Bathroom
Notes: Service Advised – Issue(s) may impact performance. Tub is also slow to drain.
Action: Clean / Repair / Monitor T: 🔵 Plumbing L: Bathroom
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Clean / Repair / Maintain T: 🔵 Plumbing L: Bathroom
Notes: Service Advised – Issue(s) may impact performance.
Action: Clean / Repair / Maintain T: 🔵 Plumbing L: Bathroom
Notes: Service Advised – Issue(s) may impact performance.
summary
Action: Correct / Adjust / Verify T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Further Evaluate T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Correct / Adjust / Verify T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Further Evaluate T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
summary
Action: Correct / Adjust / Verify T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Further Evaluate T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Correct / Adjust / Verify T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Further Evaluate T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Correct / Remove Tape L: Laundry Room
Notes: Observation – Issue(s) should be monitored; plan for maintenance or correction as needed.
summary
Action: Correct / Adjust / Verify T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Further Evaluate T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Correct / Adjust / Verify T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
Action: Further Evaluate T: 🟡 Electrical L: Laundry Room
Notes: Service Recommended – Issue(s) should be addressed by a certified professional. If left as is, this could impact performance, safety, and/or reliability.
| R BACK TO SUMMARY |
|
Report Legend
Explains reports symbols.
|
|
|
|
Roof Observations TORCH- (1)
Reviewing condition, flashings, drainage flow, debris, & intrusion points. See also Insurance Section.
Roof Observation - (2)
⠀ ⠀
|
|
|
|
Roof Observation - (3)
⠀ ⠀ ⠀
Roof Observation - (4)
⠀ ⠀ ⠀
|
|
|
|
|
|
|
Overview Roof / Property
Survey performed to visually document roof coverings & associated components.This includes material condition, install, flashing, penetrations, drainage paths, & anomalies. See also Insurance Section.
|
|
|
|
Overview Roof (2)
⠀
|
|
|
|
Overview Roof (3)
⠀
|
|
|
|
Overview Roof Utilitie(s)
Visually inspected for secure mounting, proper sealing, venting, clearances, and signs of damage, leakage, or improper installation.
|
|
|
|
Utility Vents X6
Very Minor ( Dents / Dings )
|
|
|
|
Chimneys (6 Total)
|
|
|
|
Gram-Shot
We’ve included a couple additional drone shots to provide a broader perspective of the property and its surroundings. These images offer a unique vantage point, showcasing the property’s placement within the neighborhood, nearby features, and the overall landscape.
|
|
|
|
Gram-Shot ⭐️
❤️
|
|
|
|
|
|
|
|
Extra Photos
|
|
|
|
Flashings
|
|
|
|
Facia (Metal)
|
|
|
|
|
|
|
|
The Roof Baseline O.W.L
𝗥𝗼𝗼𝗳 – 𝗔𝗿𝗲𝗮𝘀 𝗜𝗻𝘀𝗽𝗲𝗰𝘁𝗲𝗱Roof components are reviewed for presence, general condition, visible damage, and basic performance characteristics where applicable. This includes commonly accessible roofing materials, flashings, roof penetrations, drainage features, and visible edges and transitions. The review focuses on observable conditions from accessible vantage points and does not include destructive testing or prediction of remaining service life. |
|
| E BACK TO SUMMARY |
|
Actions Legend
|
|
|
|
Exterior Entry Door(s)
Inspected for condition, glazing, sealing, flashing, alignment & operation.
Interior Window(s) ⠀
Observations included glazing, operation, seals, & conditions affecting performance.
|
|
|
|
|
|
|
|
HVAC Utility Vent(s)
Inspected for installation, fittings, clearances, penetrations & sealant condition.
Additional Vent(s)
⠀⠀⠀⠀⠀⠀⠀⠀
|
|
|
|
|
|
|
|
|
|
|
⚠️ SLOPE & Grade Management
Proper grading should slope away from the foundation, not remain flat or create negative slope that directs water toward the property. Watch for heaving, settling, and high or low spots that can trap moisture near walls. Ensure downspouts discharge well away from the structure and that gutters are level and draining correctly. Poor alignment or overflow can erode soil over time, increasing the risk of moisture intrusion and foundation movement.
|
|
|
|
Drainage System(s)
Inspected for discharge location, flow, secure connections, blockage, slope & conditions directing water away from the structure.
|
|
|
|
|
|
|
|
Site Grading
Should drop a minimum of 6" every 10 feet away from the home. See also Insurance Section.
|
|
|
|
Grading & Drainage Baseline
Inspection of grading, pathways, flatwork, and drainage focused on visible slope, surface condition, and water flow around the structure. Limited to observable conditions at time of inspection.
|
|
|
|
|
Component Focus
Gas Meter(s) ⠀⠀
Observed for secure mounting, clearance, corrosion, regulator condition & visible gas line connections.
|
|
|
|
Electrical Service Meter(s)
Observed for presence, secure mounting, cover condition, clearances, conduit connections & visible service wiring concerns.
Electrical Entry.
Observations include service attachment, drip loop, clearance & visible damage or corrosion
|
|
|
Power Down, Save Up.
To boost energy efficiency, switch to LED lighting and turn off lights when not in use. Use ceiling fans and set thermostats a few degrees higher in summer and lower in winter. Unplug electronics when not in use and choose ENERGY STAR® appliances. Lower your water heater to 120°F and insulate hot water pipes. Keep filters clean and schedule regular maintenance on heating and cooling systems.
|
|
|
|
|
Focus Feature Page
These are photos related to the same component or system.
Balcony Access / Door(s)
Inspected for sealing, glazing, hardware, drainage, & signs of damage, air leakage, or intrusion.
|
|
|
|
Balcony Surface Material
Inspected to assess material condition, slope, surface wear & signs of damage,
|
|
|
The Balcony Baseline
Components are reviewed for presence, general condition, and visible signs of damage or deterioration where accessible. This includes the walking surface, guardrails, drainage, and visible structural connections. Accessible areas are checked for cracking, corrosion, rot, loose fasteners, and signs of water intrusion or improper slope. The review is limited to observable conditions without load testing, removing finishes, or evaluating concealed waterproofing or structural components.
|
|
|
|
Underside of all 6 Balconies
Older balconies with joists penetrating the exterior wall assembly. Recommend installation of proper flashing and/or elastomeric sealant at all penetration points to reduce risk of moisture intrusion. Existing flashing appears limited, and exposed wood shows age-related checking and minor splitting. No significant structural concerns observed at this time.
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| I BACK TO SUMMARY |
|
Report Legend
Explains reports symbols.
|
|
|
|
Outlet(s)
Inspected for operation, secure mounting, polarity, grounding, cover condition & visible wiring concerns.
Interior Light(s)
Inspected for operation using normal switching procedures & visible deficiencies.
|
|
|
|
Interior Door(s) ⠀
Attention given to alignment, operation, hardware, hinges, latching, & indicators affecting use.
|
|
|
|
Interior Window(s) ⠀
Observations included glazing, operation, seals, & conditions affecting performance.
Window(s) & Operation
Review for opening, closing, latching, seals, weep holes & screens. See also Insurance Section.
|
|
|
General Ceilings / Walls
Visually examined for common defects.
|
|
|
|
General Flooring
Visually examined for common defects.
|
|
|
|
About Humidity’
Maintaining proper indoor relative humidity in winter is crucial to health and comfort. Cold air holds less moisture, leading to dry indoor air when heated. Optimal indoor humidity (30-50%) prevents respiratory issues, dry skin, and damage to wood furnishings. Balancing it with outdoor temperature prevents condensation on windows and mold growth, ensuring a healthy and comfortable living environment.
|
|
|
|
|
|
|
|
The Fireplace Baseline
Components are reviewed for presence, general condition, and visible signs of damage or deterioration where accessible. This includes the fuel type, firebox, hearth, mantel, damper, and visible portions of the chimney and flue. Accessible areas are checked for soot accumulation, creosote buildup, cracks, or moisture intrusion. The review is limited to observable conditions without dismantling components or conducting internal chimney inspections.
|
|
|
|
|
Focus Feature Page
These are photos related to the same component or system.
Smoke - CO Detector(s).
Visually inspected for presence, placement, condition & power source. See also Insurance Section.
|
|
|
|
Carbon Monoxide Test(s)
Used to detect colorless, Odourless, & tasteless flammable gas. Spot checks performed in high-risk areas.
Moisture Meter Instrument
Used to measure the % of water in a given product. X10 Spot checks performed.
|
|
|
Safety First
Smoke and carbon monoxide alarms are essential life safety devices. Install smoke alarms in bedrooms, outside sleeping areas, and on every level. Install CO monitors outside sleeping areas and on each level near fuel burning appliances and attached garages.Test monthly. Replace batteries yearly. Replace units every 7 to 10 years.Keep fire extinguishers accessible in the kitchen, garage, and near mechanical equipment.
|
|
|
|
On the way out
All items tested & operated during this inspection were returned to their prior settings & positions. Windows, doors, locks, switches, and appliances are restored to their original condition, and reasonable efforts are made to tidy and leave the home as it was found at the time of inspection.
|
|
|
|
Stats set back
|
|
|
|
Stove / Oven Off
|
|
|
|
Support Photo
|
|
|
|
⚠️ Interior General Notes #1
1. Walls/Ceilings: Visible wear ( knicks & dings ), discoloration, and minor surface imperfections consistent for age.
|
|
|
|
|
Focus Feature Page
These are photos related to the same component or system.
Thermal Heat Supply
|
|
|
|
Thermal Ceilings
Thermal Wall(s)
|
|
|
|
Thermal Window(s)
Thermal Door(s)
|
|
|
|
Hot Water Thermal
Thermal P-Trap(s)
|
|
|
Thermal Dryer(s)
|
|
|
|
Thermal Toilet(s)
|
|
|
|
|
Stove tops
Ovens
|
|
|
|
Additional windows
Basement windows – frost wall
|
|
|
|
Returns
Additional registers
|
|
|
|
Hot water tanks
Additional Ptraps
|
|
|
|
Showerheads
Tub fillers
|
|
|
|
Furnace
Main panel
|
|
|
The Thermal Baseline
Observervations of surface temperature variations that may indicate areas of heat loss, moisture intrusion, or abnormal electrical or mechanical conditions where accessible. The review is limited to visible thermal patterns on exposed surfaces and does not determine the exact cause of temperature differences. Findings are influenced by environmental conditions, building materials, and time of day. This review does not include destructive testing, internal wall inspections, or verification of concealed components, and is limited to observable conditions at the time of inspection.
|
|
|
|
|
#2
Overview
Outlet(s)
Inspected for operation, secure mounting, polarity, grounding, cover condition & visible wiring concerns.
|
|
|
|
Window(s) & Operation
Review for opening, closing, latching, seals, weep holes & screens. See also Insurance Section.
Interior Window(s)
Observations included glazing, operation, seals, & conditions affecting performance.
|
|
|
Interior Door(s)
Attention given to alignment, operation, hardware, hinges, latching, & indicators affecting use.
|
|
|
|
|
|
|
|
|
#2 Thermal Overview
Thermal Heat Supply
|
|
|
|
Thermal Window(s)
Thermal Front Door
Scanned for irregularities, air leaks & consistency.
|
|
|
|
Thermal Walls
As seen from the inside. All walls & ceilings were scanned for irregularities. There are many reasons to clean drywall, from coffee st
Thermal Ceiling
We look up, down & all around. Doors, windows, or any penetration in the skeleton of your home is where we usually find the largest tem
|
|
|
|
Thermal Dryer
Thermal P-Trap
Scanned for leaks & demonstrating that it's holding water in the trap.
|
|
|
|
#3
Overview
Outlet(s)
Inspected for operation, secure mounting, polarity, grounding, cover condition & visible wiring concerns.
|
|
|
|
Window(s) & Operation
Review for opening, closing, latching, seals, weep holes & screens. See also Insurance Section.
Interior Window(s)
Observations included glazing, operation, seals, & conditions affecting performance.
|
|
|
Interior Door(s)
Attention given to alignment, operation, hardware, hinges, latching, & indicators affecting use.
|
|
|
|
|
|
|
|
|
#3 Thermal
Overview
Thermal Heat Supply
|
|
|
|
Thermal Window
Scanned for seal depletion & the presence of moisture.
Thermal Front Door
Scanned for irregularities, air leaks & consistency.
|
|
|
|
Thermal Walls
As seen from the inside. All walls & ceilings were scanned for irregularities. There are many reasons to clean drywall, from coffee st
Thermal Ceiling
We look up, down & all around. Doors, windows, or any penetration in the skeleton of your home is where we usually find the largest tem
|
|
|
|
Thermal Dryer
Thermal P-Trap
Scanned for leaks & demonstrating that it's holding water in the trap.
|
|
|
|
#4
Overview
Outlet(s)
Inspected for operation, secure mounting, polarity, grounding, cover condition & visible wiring concerns.
|
|
|
|
Window(s) & Operation
Review for opening, closing, latching, seals, weep holes & screens. See also Insurance Section.
Interior Window(s)
Observations included glazing, operation, seals, & conditions affecting performance.
|
|
|
Interior Door(s)
Attention given to alignment, operation, hardware, hinges, latching, & indicators affecting use.
|
|
|
|
|
|
|
|
|
#4 Thermal
Overview
Thermal Heat Supply
|
|
|
|
Thermal Window
Scanned for seal depletion & the presence of moisture.
Thermal Front Door
Scanned for irregularities, air leaks & consistency.
|
|
|
|
Thermal Walls
As seen from the inside. All walls & ceilings were scanned for irregularities. There are many reasons to clean drywall, from coffee st
Thermal Ceiling
We look up, down & all around. Doors, windows, or any penetration in the skeleton of your home is where we usually find the largest tem
|
|
|
|
Thermal Dryer
Thermal P-Trap
Scanned for leaks & demonstrating that it's holding water in the trap.
|
|
|
|
#5
Overview
Outlet(s)
Inspected for operation, secure mounting, polarity, grounding, cover condition & visible wiring concerns.
|
|
|
|
Window(s) & Operation
Review for opening, closing, latching, seals, weep holes & screens. See also Insurance Section.
Interior Window(s)
Observations included glazing, operation, seals, & conditions affecting performance.
|
|
|
Interior Door(s)
Attention given to alignment, operation, hardware, hinges, latching, & indicators affecting use.
|
|
|
|
|
|
|
|
|
#5 Thermal
Overview
Thermal Heat Supply
|
|
|
|
Thermal Window
Scanned for seal depletion & the presence of moisture.
Thermal Front Door
Scanned for irregularities, air leaks & consistency.
|
|
|
|
Thermal Walls
As seen from the inside. All walls & ceilings were scanned for irregularities. There are many reasons to clean drywall, from coffee st
Thermal Ceiling
We look up, down & all around. Doors, windows, or any penetration in the skeleton of your home is where we usually find the largest tem
|
|
|
|
Thermal Dryer
Thermal P-Trap
Scanned for leaks & demonstrating that it's holding water in the trap.
|
|
|
|
#6
Overview
Outlet(s)
Inspected for operation, secure mounting, polarity, grounding, cover condition & visible wiring concerns.
|
|
|
|
Window(s) & Operation
Review for opening, closing, latching, seals, weep holes & screens. See also Insurance Section.
Interior Window(s)
Observations included glazing, operation, seals, & conditions affecting performance.
|
|
|
Interior Door(s)
Attention given to alignment, operation, hardware, hinges, latching, & indicators affecting use.
|
|
|
|
|
|
|
|
|
#6 Thermal
Overview
Thermal Heat Supply
|
|
|
|
Thermal Window
Scanned for seal depletion & the presence of moisture.
Thermal Front Door
Scanned for irregularities, air leaks & consistency.
|
|
|
|
Thermal Walls
As seen from the inside. All walls & ceilings were scanned for irregularities. There are many reasons to clean drywall, from coffee st
Thermal Ceiling
We look up, down & all around. Doors, windows, or any penetration in the skeleton of your home is where we usually find the largest tem
|
|
|
|
Thermal Dryer
Thermal P-Trap
Scanned for leaks & demonstrating that it's holding water in the trap.
|
|
|
The Interior Baseline
𝗜𝗻𝘁𝗲𝗿𝗶𝗼𝗿 – 𝗔𝗿𝗲𝗮𝘀 𝗜𝗻𝘀𝗽𝗲𝗰𝘁𝗲𝗱Interior components and finishes are reviewed for presence, general condition, visible damage, and basic operation where applicable. This includes commonly accessible areas and systems such as entry spaces, walls, ceilings, floors, trim, doors, windows, stairs, electrical components, lighting, life safety devices, heating and cooling distribution elements, and other visible interior features typically found within the living space of the home. |
|
|
|
Routine Maintenance Pays
This video is provided as a helpful reference to support everyday home care & maintenance. It highlights simple steps that can reduce common problems & may help avoid unnecessary repairs or expenses over time. Watching this video may make it easier to understand the small actions that help keep a home running smoothly.See video |
|
| K BACK TO SUMMARY |
|
Report Legend
Explains reports symbols.
|
|
|
|
Microwave(s) ⠀
|
|
|
|
Refrigerator(s)
Inspected for operation, temperature control, door seal condition, water line connections, drainage, and general installation.
Support Photo
|
|
|
|
Stovetop(s) / Cooktop(s)
Inspected for basic operation, burner function, surface condition & safety concerns.
Oven(s) (SEE THERMAL)
Inspected for operation, interior condition, door sealing & visible safety concerns.
|
|
|
|
|
|
|
Kitchen Faucet(s), Sink(s) & Drain(s)
Reviewed, focused on operation, temperature, mounting, drainage, odors & leakage indicators.
|
|
|
|
Kitchen P-Trap(s)
Checked for drainage, trap configuration, connection security, leakage indicators & visible corrosion.
|
|
|
|
Kitchen Over-all
A record of what was seen this day
|
|
|
|
Support Photo
|
|
|
|
|
|
|
|
|
#2
Overview
|
|
|
|
Oven(s)
Inspected for operation, interior condition, door sealing & visible safety concerns.
Stovetop(s) / Cooktop(s)
Inspected for basic operation, burner function, surface condition & safety concerns.
|
|
|
Refrigerator(s)
Inspected for operation, temperature control, door seal condition, water line connections, drainage, and general installation.
|
|
|
|
|
|
|
|
|
#3
Overview
|
|
|
|
Oven(s)
Inspected for operation, interior condition, door sealing & visible safety concerns.
Stovetop(s) / Cooktop(s)
Inspected for basic operation, burner function, surface condition & safety concerns.
|
|
|
Refrigerator(s)
Inspected for operation, temperature control, door seal condition, water line connections, drainage, and general installation.
|
|
|
|
|
|
|
|
|
Unit / Property Focus #4
Overview
|
|
|
|
Oven(s)
Inspected for operation, interior condition, door sealing & visible safety concerns.
Stovetop(s) / Cooktop(s)
Inspected for basic operation, burner function, surface condition & safety concerns.
|
|
|
Refrigerator(s)
Inspected for operation, temperature control, door seal condition, water line connections, drainage, and general installation.
|
|
|
|
|
|
|
|
|
#5
Overview
|
|
|
|
Oven(s)
Inspected for operation, interior condition, door sealing & visible safety concerns.
|
|
|
Refrigerator(s)
Inspected for operation, temperature control, door seal condition, water line connections, drainage, and general installation.
|
|
|
|
|
|
|
|
|
#6
Overview
|
|
|
|
Stovetop(s) / Cooktop(s)
Inspected for basic operation, burner function, surface condition & safety concerns.
|
|
|
Refrigerator(s)
Inspected for operation, temperature control, door seal condition, water line connections, drainage, and general installation.
|
|
|
|
|
|
|
|
The Kitchen Baseline
Components are reviewed for presence, general condition, and visible signs of damage or deterioration where accessible. This includes cabinetry, countertops, sinks, faucets, visible plumbing connections, built-in appliances, wall and ceiling finishes, and accessible electrical outlets. Accessible areas are checked for leaks, staining, loose or damaged finishes, improper clearances, and signs of moisture intrusion. The review is limited to observable conditions without moving appliances, dismantling components, or evaluating concealed plumbing, electrical, or ventilation systems.
|
|
|
|
The Laundry Baseline
Components are reviewed for presence, general condition, and visible signs of damage or deterioration where accessible. This includes cabinetry, countertops, sinks, faucets, built-in appliances, visible plumbing connections, wall and ceiling finishes, and accessible electrical receptacles. Accessible areas are checked for leaks, staining, loose or damaged finishes, improper clearances, and signs of moisture intrusion. The review is limited to observable conditions without moving appliances, dismantling components, or evaluating concealed plumbing, electrical, or ventilation systems.
|
|
| L BACK TO SUMMARY |
|
Report Legend
Explains reports symbols.
|
|
|
|
Laundry Washer Machine
Reviewed, focused on plumbing connections, hoses, drains, seals & visible leakage.
Inside The Washer
|
|
|
|
Laundry Dryer(s).
Attention given to operation, temperature variance, vent connections & lint accumulation.
Inside The Dryer
|
|
|
|
VENT - VENT - VENT
Door & drawer OPEN to let moisture escape & prevent organic growth.
RISK Reduction
Check behind the washer for leaks regularly, and shut off the water when away on vacation.
|
|
|
|
|
|
|
|
Laundry Dryer(s).
Attention given to operation, temperature variance, vent connections & lint accumulation.
|
|
|
|
Laundry Washer Machine
Reviewed, focused on plumbing connections, hoses, drains, seals & visible leakage.
Inside The Washer
|
|
|
#2
Overview
|
|
|
|
|
|
|
|
|
Laundry Dryer(s).
Attention given to operation, temperature variance, vent connections & lint accumulation.
Inside The Dryer
|
|
|
|
Laundry Washer Machine
Reviewed, focused on plumbing connections, hoses, drains, seals & visible leakage.
Inside The Washer
|
|
|
Unit / Property Focus #3
Overview
|
|
|
|
|
|
|
|
|
Inside The Dryer
|
|
|
|
Laundry Washer Machine
Reviewed, focused on plumbing connections, hoses, drains, seals & visible leakage.
Inside The Washer
Undetermined: Results unclear due to conditions or limitations (seller items). Further review needed to confirm the situation.. Not Inspected
|
|
|
#4
Overview
|
|
|
|
|
|
|
|
|
Laundry Dryer(s)
Attention given to operation, temperature variance, vent connections & lint accumulation.
|
|
|
|
Laundry Washer Machine
Undetermined: Results unclear due to conditions or limitations (seller items). Further review needed to confirm the situation.. Not Inspected
Inside The Washer
|
|
|
#5
Overview
|
|
|
|
|
|
|
|
|
Laundry Dryer(s)
Attention given to operation, temperature variance, vent connections & lint accumulation.
Inside The Dryer
|
|
|
|
Laundry Washer Machine #6
Reviewed, focused on plumbing connections, hoses, drains, seals & visible leakage.
Inside The Washer
|
|
|
#6
Overview
|
|
|
|
|
|
| B BACK TO SUMMARY |
|
Report Legend
Explains reports symbols.
|
|
|
|
Bathroom Outlet(s)
Tested for anomalies.
Bathroom Extraction Fan(s)
Observations included basic operation & airflow response using simple draw testing.
|
|
|
|
|
|
|
|
Bathroom Water Faucet(s)
Operated to assess function, flow, mounting, sealing & signs of leakage, corrosion, or wear.
Bathroom Sink Drain(s)
|
|
|
Bathroom P-Trap(s)
Checked for drainage, trap configuration, connection security, leakage indicators & visible corrosion.
|
|
|
|
Toilet(s)
Reviewed for stability, operation & visible leakage. X3 flush test per unit.
|
|
|
|
General Ceilings / Walls
Visually examined for common defects.
|
|
|
|
General Flooring
Visually examined for common defects.
|
|
|
|
Bathtub & Surround(s)
Inspected for condition, secure installation, functional drainage, faucet operation, and visible signs of leaks, cracks, damage, or deteriorated sealant at accessible areas.
|
|
|
|
|
|
|
|
|
#2
Overview
Bathroom Outlet(s)
Tested for anomalies.
|
|
|
|
|
|
|
The Toilets
X3 flush test and observe if it flushes properly, refills the tank adequately, and does not exhibit any signs of leakage around the base or connections. Additionally, checked if the bowl and tank components, like the flapper and fill valve, are functioning correctly.
|
|
|
|
|
|
|
|
|
#3
Overview
|
|
|
|
Overview Shower / Bathtub
Focused on fixtures, connections, operation, overflows & surrounds.
|
|
|
Toilet(s)
Reviewed for stability, operation & visible leakage. X3 flush test per unit.
|
|
|
|
|
|
|
|
|
#4
Overview
|
|
|
|
Overview Shower / Bathtub
Focused on fixtures, connections, operation, overflows & surrounds.
Bathroom Faucet / Sink
Faucets, tub fillers & shower heads were fully tested.
|
|
|
Toilet(s)
Reviewed for stability, operation & visible leakage. X3 flush test per unit.
|
|
|
|
|
|
|
|
|
#5
Overview
|
|
|
|
Overview Shower / Bathtub
Focused on fixtures, connections, operation, overflows & surrounds.
|
|
|
Toilet(s)
Reviewed for stability, operation & visible leakage. X3 flush test per unit.
|
|
|
|
|
|
|
|
|
#6
Overview
|
|
|
|
Overview Shower / Bathtub
Focused on fixtures, connections, operation, overflows & surrounds.
Bathroom Faucet / Suite
Faucets, tub fillers & shower heads were fully tested.
|
|
|
Toilet(s)
Reviewed for stability, operation & visible leakage. X3 flush test per unit.
|
|
|
|
|
|
|
|
Bathroom Ventilation
Bathroom exhaust fans help remove excess moisture created during bathing and showering. Running the fan during use and for at least 15–20 minutes afterward helps reduce humidity, which can prevent condensation, microbial growth, peeling finishes, and moisture damage to walls, ceilings, and nearby materials. Regular use and periodic cleaning of the fan grille improve performance and indoor air quality.
|
|
|
|
The Bathroom Baseline
Components are reviewed for presence, general condition, and visible signs of damage or deterioration where accessible. This includes cabinetry, countertops, sinks, faucets, visible plumbing, appliances, wall and ceiling finishes, and electrical receptacles. Accessible areas are checked for leaks, staining, loose or damaged finishes, improper clearances, and signs of moisture intrusion. The review is limited to observable conditions without moving appliances, dismantling components, or evaluating concealed plumbing, electrical, or ventilation systems.
|
|
| M BACK TO SUMMARY |
|
Report Legend
Explains reports symbols.
|
|
|
|
|
|
|
|
Hot Water Unit - 2008
Attention was given to unit mounting, venting, safety components, temperature controls & visbile operation.
Hot Water Data
Unit detail(s). See also Insurance Section.
|
|
|
|
The Main Heating Unit - 2006
Observations included mounts, venting, ducts, filters, clearances & visible performance.
Heating Unit Data Plate
Unit detail(s). See also Insurance Section.
|
|
|
|
Heating Unit Shutoff
Observed for accessibility, labeling, secure mounting & operation affecting emergency shutoff capability.
Water Main Shutoff ⠀
Assessing valve operation & signs of leakage, corrosion, or damage. See also Insurance Section.
|
|
|
|
Plumbing Waterlines
Inspected for support, connections, leaks & visible corrosion or damage. See also Insurance Section.
Ext. Water Shutoff(s)
Observed for accessibility, labels, valve operation, connection condition & leakage indicators. Not Accessible: Area or item could not be accessed at the time of inspection and was therefore not evaluated.. Not Inspected
|
|
|
Maintenance Advisory
Mechanical systems require routine homeowner maintenance and periodic observation for safe operation. This includes replacing heating system filters as recommended, keeping drains and condensate lines clear of debris, and periodically having sewer lines evaluated by a qualified contractor. Safety measures include maintaining domestic hot water at a safe temperature and installing locking or spring-loaded cover plates on critical controls to prevent accidental shutoff. Occupants should be familiar with all system shutoffs and label them clearly. Mechanical rooms should not be used for storage due to required clearance to combustibles. Homeowners should periodically check the mechanical room for calcification, minor leaks, corrosion, or unusual odors that may indicate developing issues.
|
|
|
|
Stair(s) & Railing(s)
Attention was given to structure, rise/run consistency, landings, string if visible, handrails, & visible safety indicators.
|
|
|
|
Stairs & Railings Baseline
Stairs & Railings – Areas Inspected Inspection of the stairs focused on accessible structural and safety conditions. This included treads, risers, stringers, landings, handrails, and guards where present. Components were reviewed for secure attachment, uniformity, damage, wear, and trip or fall hazards. The evaluation was limited to visible and accessible areas without dismantling components or assessing concealed structural elements. |
|
|
|
General Ceilings / Walls
Visually examined for common defects.
|
|
|
|
General Flooring
Visually examined for common defects.
|
|
|
|
Framing 101
Behind every wall is a framework — much like your own skeleton. Vertical studs form the bones, while cripples support around openings. King and jack studs work together to hold up headers over doors and windows, spreading the load. Top plates cap the walls and tie everything together, while bottom plates anchor it all to the floor. This unseen structure is critical to the strength, stability, and alignment of your home. Just like a healthy body depends on solid bones, your home depends on this framing to stand true. ⠀⠀⠀⠀⠀ ⠀ ⚠️ See also Insurance section for more details on your the structural specifications of this property.
|
|
|
|
|
|
|
|
|
#2
Overview
Heating Unit Shutoff ⠀⠀⠀
Observed for accessibility, labeling, secure mounting & operation affecting emergency shutoff capability.
|
|
|
|
The Main Heating Unit - 2006
Observations included mounts, venting, ducts, filters, clearances & visible performance.
Heating Unit Data Plate
Unit detail(s). See also Insurance Section.
|
|
|
|
Hot Water Tank - 2025
Attention was given to unit mounting, venting, safety components, temperature controls & visbile operation.
Hot Water Data
Unit detail(s). See also Insurance Section.
|
|
|
|
|
|
|
|
|
|
|
|
#3
Overview
Heating Unit Shutoff ⠀⠀⠀
Observed for accessibility, labeling, secure mounting & operation affecting emergency shutoff capability.
|
|
|
|
The Main Heating Unit - 2007
Observations included mounts, venting, ducts, filters, clearances & visible performance.
Heating Unit Data Plate
Unit detail(s). See also Insurance Section.
|
|
|
|
Hot Water Tank - 2020
Attention was given to unit mounting, venting, safety components, temperature controls & visbile operation.
Hot Water Data
Unit detail(s). See also Insurance Section.
|
|
|
|
|
|
|
|
|
|
|
|
#4
Overview
Heating Unit Shutoff ⠀⠀⠀
Observed for accessibility, labeling, secure mounting & operation affecting emergency shutoff capability.
|
|
|
|
The Main Heating Unit - 2006
Observations included mounts, venting, ducts, filters, clearances & visible performance.
Heating Unit Data Plate
Unit detail(s). See also Insurance Section.
|
|
|
|
Hot Water Unit - 2011
Hot Water Data
Unit detail(s). See also Insurance Section.
|
|
|
|
|
|
|
|
|
|
|
|
#5
Overview
|
|
|
|
The Main Heating Unit - 2006
Observations included mounts, venting, ducts, filters, clearances & visible performance.
Heating Unit Data Plate
Unit detail(s). See also Insurance Section.
|
|
|
|
Hot Water Unit - 2011
Attention was given to unit mounting, venting, safety components, temperature controls & visbile operation.
Hot Water Data
Unit detail(s). See also Insurance Section.
|
|
|
|
|
|
|
|
|
|
|
|
#6
Overview
Heating Unit Shutoff ⠀⠀⠀
Observed for accessibility, labeling, secure mounting & operation affecting emergency shutoff capability.
|
|
|
|
The Main Heating Unit - 2006
Observations included mounts, venting, ducts, filters, clearances & visible performance.
Heating Unit Data Plate
Unit detail(s). See also Insurance Section.
|
|
|
|
Hot Water Unit - 2011
Attention was given to unit mounting, venting, safety components, temperature controls & visbile operation.
Hot Water Data
Unit detail(s). See also Insurance Section.
|
|
|
|
|
|
|
|
|
|
|
The Mechanical Baseline
𝗠𝗲𝗰𝗵𝗮𝗻𝗶𝗰𝗮𝗹 – 𝗔𝗿𝗲𝗮𝘀 𝗜𝗻𝘀𝗽𝗲𝗰𝘁𝗲𝗱Mechanical components and systems are reviewed for presence, general condition, visible damage, and basic operation where applicable. This includes commonly accessible heating, cooling, and ventilation equipment, water heating equipment, visible piping and ductwork, pumps, valves, and associated controls. Supporting components and other mechanical features typically found within the home are also visually reviewed where present. 𝗦𝘁𝗿𝘂𝗰𝘁𝘂𝗿𝗲 – 𝗔𝗿𝗲𝗮𝘀 𝗜𝗻𝘀𝗽𝗲𝗰𝘁𝗲𝗱 Structural components are reviewed for presence, general condition, and visible signs of damage or movement where applicable. This includes commonly accessible foundation surfaces, framing elements, beams, posts, columns, load-bearing walls, and other visible structural features. The review focuses on observable conditions within accessible areas and does not include engineering analysis or invasive evaluation. |
|
insurance
| Safety Overview | |
| Site Limitations | ⚠️ Visibility - Access - Height |
| Inspection Type | ◻️ Pre-Purchase X6 Inspection (non-exhaustive) |
| Property Vacancy | ◻️ Occupied & Furnished (restrictive) |
| Smoke & CO | ⚠️ Not Verified: Unable to confirm function |
| Egress Windows | ◻️ Location: All Bedroom(s): Present |
| Stairs & Handholds | ◻️ Structure: Functioning as Intended |
| Roof System | |
| Method of Inspection | ◻️ Ladder at edge, walked & drone |
| Roofing Surface | ◻️ Material: Mod Bitumen - Age: New |
| Drainage Path | ◻️ System: Trough - Scupper & Downspouts |
| Ventilation System | ◻️ Passive Vent(s) & Partial Perforated Soffit |
| Exterior Overview | |
| Cooling Type(s) | ◻️ Not Present - Not Applicable |
| Main Fuel Shutoff | ◻️ Location: Side Yard x6 (Wood Cabinet) |
| Envelope Cladding | ◻️ Material: Brick - Grandma Stucco (Flaking) |
| Steps & Guards | ◻️ Materials: Concrete Stairs & No Railing |
| Barriers & Walls | ◻️ Material: Metal Chain Link (fence) |
| Grade & Ground Cover | ⚠️ Terrain: Negative Slope - Vegitation |
| Hardscape Surfaces | ◻️ Material: Paths: Concrete (Settlement Cracks) |
| Garage Systems | |
| Fire Seperation | ◻️ Not Applicable |
| Safety Auto Reverse | ◻️ Status: Not Applicable |
| Heating Equipment | ◻️ Unit: Not Applicable |
| Attic System | |
| Hatch & Insulation | ⚠️ Location: Laundry - Mat: Unknown (Batt?) |
| Sheathing & Poly | ⚠️ Material: Unknown - Vap Barrier: Unknown |
insurance
| Interior Overview | |
| Thermostat Location | ◻️ Location: Main Level - Restored to original |
| Walls & Ceilings | ◻️ Material: Drywall (Tongue & Groove Ceiling) |
| Flooring Surfaces | ◻️ Material: Laminate - Tile - Carpet |
| Other Features | ⚠️ Type: Wood Fireplace (RCMD WETT Inspection) |
| Kitchen & Bathroom | |
| Safety - GFCI’s | ⚠️ Location: Kitchen: NP - Bath: Present |
| Ventilation System | ◻️ Type: Range Hood: to EXT. - B-Fan: Present |
| Laundry Specs | ◻️ 220V - Vent: Metal - Water: Braided |
| Mechanical System | |
| Heating Unit(s) | ◻️ Type: Mid Furnace / Forced Air - Age: 2006? |
| Heating Fuel Source | ◻️ Type: Natural Gas - Primary |
| Water Heater Unit | ◻️ Type: Tank 40 Gal - Age: 2008 |
| Water Heating Fuel | ◻️ Type: Natural Gas - Primary |
| Plumbing System | ◻️ Public Water: Copper - City Sewer: ABS |
| Water Main Shutoff | ◻️ Location: Basement (Back Bedroom) |
| Back Flow Valve | ⚠️ Installation: Unknown |
| Electrical Service | ◻️ Entry: Overhead - Material: Unknown? |
| Service Disconnect | ◻️ Location: Not Present |
| Main Panel Interior | ◻️ Location: Mech Room - Ground: Unknown |
| Electrical System | ⚠️ Service: 60 AMP - Branch: Aluminum (RISK) |
| Structure System | |
| Roof Structure | ⚠️ Type: Undetermined - Unknown (Dimensional) |
| Exterior Wall System | ◻️ Type: Wood Studs (99% Not Visible) |
| Structure System | ◻️ Type: Dimensional Wood Frame (99% Not Visible) |
| Foundation System | ◻️ Type: Poured Concrete (99% Not Visible) |
| Structural Observ. | ◻️ Notes: Minor settlement |